7 Drive Machine Data (SIMODRIVE Drive MD) 04.96
7.3.2 Drive MD (data description)
Segment memory location monitor
1655
Default value Lower input limit Upper input limit Units
0 0 1
Active
at once
This machine data addresses the memory location segment for the monitoring function.
Value table:
0 DSP address space X
1 DSP address space Y
MD 1655 defines the DSP address in conjunction with MD 1656 (offset address). The contents
of the DSP address can be displayed via machine data "Value display monitor" (MD 1657).
Caution:
This machine data is relevant only for Siemens-internal purposes and must not be altered.
Address memory location monitor
1656
Default value Lower input limit Upper input limit Units
0000 0000 FFFF Hex
Active
at once
This machine data addresses the memory location offset address for the monitoring function.
MD 1656 defines the DSP address in conjunction with MD 1655 (memory location segment).
The contents of the DSP address can be displayed via machine data "Value display monitor"
(MD 1657).
Caution:
This machine data is relevant only for Siemens-internal purposes and must not be altered.
7–152 ©
Siemens AG 1992 All Rights Reserved 6FC5197- AA50